How It Works Under the Hood
IPC-2221 gives the allowed current as I = k × ΔT^0.44 × A^0.725, where A is the copper cross-section in square mils, ΔT is the temperature rise in °C and k is 0.048 for outer layers and 0.024 for inner layers. The tool inverts it to get the area for a current, then divides by copper thickness (1 oz is about 1.378 mil, or 35 µm) to get the width.
Step-by-Step Instructions
Enter the current and the temperature rise you can accept.
Choose copper weight and whether the trace is on an external or internal layer.
Optionally enter the trace length to get resistance and voltage drop.
Read the width in mm and mil.
Key Features & Performance
- Width from current, or current from width
- External and internal layers
- Resistance and voltage drop for a trace length
- Millimetre and mil results
Methodology, Formulas & Technical Standards
IPC-2221 curves were fitted for currents up to about 35 A, widths up to 400 mil and rises of 10 to 100 °C. Resistance uses copper at 20 °C.
Worked Examples & Edge Cases
3 A on an outer layer
3 A, 10 °C rise, 1 oz copper, external
about 1.37 mm wide
An inner layer needs more than twice the width.
Limitations, Scope & Accuracy Notes
- • IPC-2221 is conservative for external layers and less accurate for very high currents; IPC-2152 gives better data when you need it.
- • It ignores nearby heat sources, copper pours that help cooling and vias, so check hot designs by test.
Local Browser Processing & Privacy
Traditional web converters upload your documents, snippets, or media files to remote servers. PCB Trace Width & Current Capacity Calculator runs inside your browser tab:
Your input text and files are processed locally without uploading payloads to a processing server.
Microdeck does not log or store the files or inputs you paste into tool workspaces (normal static hosting/CDN requests still load page assets).
Working outputs stay in your browser tab and are released when you reset the tool or close the tab.
Frequently Asked Questions
Why are internal traces wider?
Inner copper is surrounded by laminate and cannot shed heat to air, so the same current causes a bigger temperature rise.
What temperature rise should I pick?
10 °C is a common safe choice. Higher rises save space but heat the board and nearby parts.
Does this replace a design rule check?
No. It is a quick estimate; confirm with your fab and safety standards, especially for mains voltages.
Explore Related Micro-Tools
Wire Gauge (AWG) & Voltage Drop Calculator
Pick the wire size for a current and run length, or check the voltage drop of a given wire
Ohm's Law & Power Calculator
Enter any two of voltage, current, resistance or power and get the other two
Resistor Color Code Calculator
4, 5 and 6 band resistors: colors to value, value to colors, nearest E24