IPC-2221 gives the allowed current as I = k × ΔT^0.44 × A^0.725, where A is the copper cross-section in square mils, ΔT is the temperature rise in °C and k is 0.048 for outer layers and 0.024 for inner layers. The tool inverts it to get the area for a current, then divides by copper thickness (1 oz is about 1.378 mil, or 35 µm) to get the width.
Panduan Langkah demi Langkah
Enter the current and the temperature rise you can accept.
Choose copper weight and whether the trace is on an external or internal layer.
Optionally enter the trace length to get resistance and voltage drop.
Read the width in mm and mil.
Fitur Utama & Performa
- Width from current, or current from width
- External and internal layers
- Resistance and voltage drop for a trace length
- Millimetre and mil results
Metodologi, Rumus & Standar Teknis
IPC-2221 curves were fitted for currents up to about 35 A, widths up to 400 mil and rises of 10 to 100 °C. Resistance uses copper at 20 °C.
Contoh Kasus & Uji Coba
3 A on an outer layer
3 A, 10 °C rise, 1 oz copper, external
about 1.37 mm wide
An inner layer needs more than twice the width.
Catatan Batasan & Akurasi
- • IPC-2221 is conservative for external layers and less accurate for very high currents; IPC-2152 gives better data when you need it.
- • It ignores nearby heat sources, copper pours that help cooling and vias, so check hot designs by test.
Pemrosesan Lokal di Browser & Privasi
Konverter web konvensional mengunggah dokumen, teks, atau media ke server jarak jauh. Kalkulator Lebar Jalur PCB & Kapasitas Arus berjalan langsung di tab browser Anda:
Teks dan file Anda diproses secara lokal tanpa mengirim muatan apa pun ke server.
Microdeck tidak mencatat atau menyimpan file dan teks yang Anda masukkan ke ruang kerja alat.
Hasil kerja hanya tersimpan di memori tab dan langsung terhapus saat Anda me-reset atau menutup tab.
Pertanyaan yang Sering Diajukan (FAQ)
Why are internal traces wider?
Inner copper is surrounded by laminate and cannot shed heat to air, so the same current causes a bigger temperature rise.
What temperature rise should I pick?
10 °C is a common safe choice. Higher rises save space but heat the board and nearby parts.
Does this replace a design rule check?
No. It is a quick estimate; confirm with your fab and safety standards, especially for mains voltages.
Jelajahi Alat Mikro Terkait
Kalkulator Ukuran Kabel (AWG) & Jatuh Tegangan
Pilih ukuran kabel berdasarkan arus dan panjang, atau periksa jatuh tegangan
Kalkulator Hukum Ohm & Daya
Masukkan dua dari tegangan, arus, hambatan, atau daya untuk mendapat dua lainnya
Kalkulator Kode Warna Resistor
Resistor 4, 5, dan 6 gelang: warna ke nilai, nilai ke warna, E24 terdekat