Fonctionnement technique
IPC-2221 gives the allowed current as I = k × ΔT^0.44 × A^0.725, where A is the copper cross-section in square mils, ΔT is the temperature rise in °C and k is 0.048 for outer layers and 0.024 for inner layers. The tool inverts it to get the area for a current, then divides by copper thickness (1 oz is about 1.378 mil, or 35 µm) to get the width.
Mode d’emploi étape par étape
Enter the current and the temperature rise you can accept.
Choose copper weight and whether the trace is on an external or internal layer.
Optionally enter the trace length to get resistance and voltage drop.
Read the width in mm and mil.
Fonctionnalités & performances
- Width from current, or current from width
- External and internal layers
- Resistance and voltage drop for a trace length
- Millimetre and mil results
Méthodologie, formules & standards
IPC-2221 curves were fitted for currents up to about 35 A, widths up to 400 mil and rises of 10 to 100 °C. Resistance uses copper at 20 °C.
Exemples concrets & cas limites
3 A on an outer layer
3 A, 10 °C rise, 1 oz copper, external
about 1.37 mm wide
An inner layer needs more than twice the width.
Limites & notes de précision
- • IPC-2221 is conservative for external layers and less accurate for very high currents; IPC-2152 gives better data when you need it.
- • It ignores nearby heat sources, copper pours that help cooling and vias, so check hot designs by test.
Traitement local dans le navigateur & confidentialité
Les convertisseurs classiques envoient vos documents, extraits ou médias sur des serveurs distants. Largeur de piste PCB et courant admissible s’exécute directement dans votre onglet :
Vos textes et fichiers sont traités localement sans aucun envoi vers un serveur de calcul.
Microdeck n’enregistre ni ne stocke les fichiers ou données collés dans les outils.
Les résultats restent dans la mémoire de votre onglet et sont libérés dès que vous le fermez.
Questions fréquentes (FAQ)
Why are internal traces wider?
Inner copper is surrounded by laminate and cannot shed heat to air, so the same current causes a bigger temperature rise.
What temperature rise should I pick?
10 °C is a common safe choice. Higher rises save space but heat the board and nearby parts.
Does this replace a design rule check?
No. It is a quick estimate; confirm with your fab and safety standards, especially for mains voltages.
Outils associés à découvrir
Section de fil (AWG) et chute de tension
Choisir la section selon le courant et la longueur, ou vérifier la chute de tension
Calculateur loi d’Ohm et puissance
Entrez deux valeurs parmi tension, courant, résistance et puissance
Calculateur de code couleur des résistances
Résistances à 4, 5 et 6 anneaux : couleurs vers valeur, valeur vers couleurs, E24 le plus proche