Cómo funciona por dentro
IPC-2221 gives the allowed current as I = k × ΔT^0.44 × A^0.725, where A is the copper cross-section in square mils, ΔT is the temperature rise in °C and k is 0.048 for outer layers and 0.024 for inner layers. The tool inverts it to get the area for a current, then divides by copper thickness (1 oz is about 1.378 mil, or 35 µm) to get the width.
Instrucciones paso a paso
Enter the current and the temperature rise you can accept.
Choose copper weight and whether the trace is on an external or internal layer.
Optionally enter the trace length to get resistance and voltage drop.
Read the width in mm and mil.
Funciones principales y ventajas
- Width from current, or current from width
- External and internal layers
- Resistance and voltage drop for a trace length
- Millimetre and mil results
Metodología, fórmulas y estándares técnicos
IPC-2221 curves were fitted for currents up to about 35 A, widths up to 400 mil and rises of 10 to 100 °C. Resistance uses copper at 20 °C.
Ejemplos prácticos y casos límite
3 A on an outer layer
3 A, 10 °C rise, 1 oz copper, external
about 1.37 mm wide
An inner layer needs more than twice the width.
Límites y notas de precisión
- • IPC-2221 is conservative for external layers and less accurate for very high currents; IPC-2152 gives better data when you need it.
- • It ignores nearby heat sources, copper pours that help cooling and vias, so check hot designs by test.
Procesamiento local en tu navegador y privacidad
Los conversores tradicionales suben tus documentos, textos o archivos multimedia a servidores remotos. Ancho de pista PCB y capacidad de corriente se ejecuta dentro de tu pestaña:
Tus textos y archivos se procesan localmente sin enviarse a ningún servidor externo.
Microdeck no guarda ni registra el contenido que introduces en las herramientas.
Los resultados permanecen en la memoria de tu navegador y se liberan al cerrar o reiniciar.
Preguntas frecuentes (FAQ)
Why are internal traces wider?
Inner copper is surrounded by laminate and cannot shed heat to air, so the same current causes a bigger temperature rise.
What temperature rise should I pick?
10 °C is a common safe choice. Higher rises save space but heat the board and nearby parts.
Does this replace a design rule check?
No. It is a quick estimate; confirm with your fab and safety standards, especially for mains voltages.
Explora herramientas relacionadas
Calibre de cable (AWG) y caída de tensión
Elegir el cable según corriente y longitud, o comprobar la caída de tensión
Calculadora de ley de Ohm y potencia
Introduzca dos de tensión, corriente, resistencia o potencia y obtenga las otras dos
Calculadora de código de colores de resistencias
Resistencias de 4, 5 y 6 bandas: colores a valor, valor a colores, E24 más cercano