底層運作原理
In astable mode the capacitor charges through R1 and R2 and discharges through R2, so the output high time is 0.693 × (R1 + R2) × C and the low time is 0.693 × R2 × C. In monostable mode one trigger gives one pulse of 1.1 × R × C. The tool does both and shows the period, frequency and duty cycle.
詳細操作步驟
Choose astable or monostable.
Enter the resistors and the capacitor, for example 1k, 10k and 10n.
Read the frequency, period, high and low times, or the pulse width.
核心功能與效能優勢
- Astable and monostable
- Frequency, period, high time, low time and duty cycle
- SI suffix input
- Warns about a too-small R1
運算方法、公式與技術標準
Astable: f = 1 / (ln2 × (R1 + 2R2) × C). Monostable: T = ln3 × R × C ≈ 1.1 × R × C.
實作範例與邊界案例
R1 1k, R2 10k, C 10n
Astable
≈ 6.9 kHz, duty ≈ 52%
R 100k, C 10n
Monostable
≈ 1.1 ms
使用限制與精準度說明
- • Tolerance of the 555 and the components shifts the result by several percent.
- • The standard astable circuit cannot give a duty cycle below 50%.
瀏覽器本地運算與隱私保障
傳統線上轉換網站會將您的文件、文字片段或影音檔案上傳至遠端伺服器。555 定時器計算器 (無穩態與單穩態振盪) 完全在您的瀏覽器分頁內運行:
您的檔案與文字都在裝置本機計算,不會傳送內容至任何後端伺服器。
Microdeck 不會記錄或儲存您在工具內貼上的任何檔案或程式碼。
所有暫存結果僅存在目前分頁記憶體中,重設或關閉分頁後即刻清除。
常見問題 (FAQ)
How do I get a 50% duty cycle?
Add a diode in parallel with R2, or divide the output by two with a flip-flop.
Does it work for NE555, LM555 and the CMOS 7555?
Yes, the timing equations are the same.
Is anything stored?
No.