仕組みと内部処理
A strain gauge changes resistance by GF × strain. In a Wheatstone bridge that becomes a small voltage: a quarter bridge gives about GF × strain ÷ 4 per volt of excitation, a half bridge GF × strain ÷ 2 and a full bridge GF × strain. Enter the gauge factor, excitation and strain, or a measured output to get the strain.
使い方ステップ
Choose strain → output or output → strain.
Pick the bridge configuration.
Enter gauge factor, excitation voltage and the value.
Read the result and the amplifier gain suggestion.
主な機能と特長
- Quarter, half and full bridge
- Exact quarter-bridge non-linearity
- mV and mV/V
- Amplifier gain for an ADC range
計算ロジック・仕様・技術基準
Quarter: Vout/Vex = (GF·ε/4)/(1 + GF·ε/2). Half: GF·ε/2. Full: GF·ε.
入出力の例・エッジケース
1000 µε, GF 2.1, 5 V
Quarter bridge
≈ 2.6 mV
仕様上の制限・精度に関するご注意
- • Lead-wire resistance, temperature and bridge imbalance are not included.
- • Assumes equal bridge resistors.
ブラウザ内ローカル処理とプライバシー保護
一般的なWebツールは文書やメディアを外部サーバーへ送信します。ホイートストンブリッジ計算機 (ひずみゲージ・ロードセル) はお使いのブラウザタブ内のみで完結します:
入力テキストやファイルは端末内で処理され、外部の処理サーバーへアップロードされません。
作業内容や貼り付けたデータを保存・記録しません(通常の静的配信CDNリクエストのみ発生します)。
作業データはタブ内のメモリ上のみに保持され、リセットまたはタブを閉じると破棄されます。
よくある質問 (FAQ)
What is µε?
Microstrain: 10⁻⁶ change in length per length.
Why is the signal so small?
Typical outputs are a few mV, so an instrumentation amplifier is needed.
Is data uploaded?
No.