Cara Kerja di Balik Layar
A strain gauge changes resistance by GF × strain. In a Wheatstone bridge that becomes a small voltage: a quarter bridge gives about GF × strain ÷ 4 per volt of excitation, a half bridge GF × strain ÷ 2 and a full bridge GF × strain. Enter the gauge factor, excitation and strain, or a measured output to get the strain.
Panduan Langkah demi Langkah
Choose strain → output or output → strain.
Pick the bridge configuration.
Enter gauge factor, excitation voltage and the value.
Read the result and the amplifier gain suggestion.
Fitur Utama & Performa
- Quarter, half and full bridge
- Exact quarter-bridge non-linearity
- mV and mV/V
- Amplifier gain for an ADC range
Metodologi, Rumus & Standar Teknis
Quarter: Vout/Vex = (GF·ε/4)/(1 + GF·ε/2). Half: GF·ε/2. Full: GF·ε.
Contoh Kasus & Uji Coba
1000 µε, GF 2.1, 5 V
Quarter bridge
≈ 2.6 mV
Catatan Batasan & Akurasi
- • Lead-wire resistance, temperature and bridge imbalance are not included.
- • Assumes equal bridge resistors.
Pemrosesan Lokal di Browser & Privasi
Konverter web konvensional mengunggah dokumen, teks, atau media ke server jarak jauh. Kalkulator Jembatan Wheatstone (Strain Gauge & Load Cell) berjalan langsung di tab browser Anda:
Teks dan file Anda diproses secara lokal tanpa mengirim muatan apa pun ke server.
Microdeck tidak mencatat atau menyimpan file dan teks yang Anda masukkan ke ruang kerja alat.
Hasil kerja hanya tersimpan di memori tab dan langsung terhapus saat Anda me-reset atau menutup tab.
Pertanyaan yang Sering Diajukan (FAQ)
What is µε?
Microstrain: 10⁻⁶ change in length per length.
Why is the signal so small?
Typical outputs are a few mV, so an instrumentation amplifier is needed.
Is data uploaded?
No.
Jelajahi Alat Mikro Terkait
Kalkulator Termistor NTC
Hitung suhu dari nilai resistansi atau sebaliknya menggunakan rumus koefisien Beta
Kalkulator Pembagi Tegangan
Tegangan keluaran dari dua resistor, atau R2 untuk tegangan target, dengan efek beban
Kalkulator Desibel (dB, dBm, dBW, dBu, dBV)
Konversi dB daya (10 log) dan dB voltase (20 log); ubah dBm ke Watt