Microdeck.tools 100% In-Browser

Orifice Plate Flow Rate Calculator

New

Calculate the flow rate through a sharp-edged orifice plate from the differential pressure, pipe and orifice diameters, or the pressure drop needed for a flow.

100% In-Browser No Server Storage Instant Results

Did this tool save you time? Help keep Microdeck free and maintained. Completely optional · From $3.

How It Works Under the Hood

A narrow orifice speeds the fluid up and drops the pressure. The flow follows Q = Cd × A × √(2ΔP/ρ) divided by √(1 − β⁴), where β is the orifice-to-pipe diameter ratio. Enter the two diameters, the fluid density and the pressure drop to get the flow, or enter a flow to get the pressure drop.

Step-by-Step Instructions

1

Choose flow from pressure or pressure from flow.

2

Enter the pipe and orifice diameters.

3

Enter the fluid density and the discharge coefficient.

4

Read the flow in several units, or the pressure drop.

Key Features & Performance

  • Both directions
  • m³/h, L/min, L/s and kg/s
  • Orifice velocity and β ratio
  • Warning outside the usual β range

Methodology, Formulas & Technical Standards

Q = Cd × A × √(2ΔP/ρ) ÷ √(1 − β⁴).

Worked Examples & Edge Cases

25 mm orifice in a 50 mm pipe

Input
20 kPa, water
Output
About 7.0 m³/h

Limitations, Scope & Accuracy Notes

  • • Incompressible, single-phase flow at high Reynolds numbers.
  • • Gas flow at large pressure drops needs an expansion factor.

Local Browser Processing & Privacy

Traditional web converters upload your documents, snippets, or media files to remote servers. Orifice Plate Flow Rate Calculator runs inside your browser tab:

Processed in This Tab

Your input text and files are processed locally without uploading payloads to a processing server.

No Tool Payload Logging

Microdeck does not log or store the files or inputs you paste into tool workspaces (normal static hosting/CDN requests still load page assets).

Tab Memory Lifecycle

Working outputs stay in your browser tab and are released when you reset the tool or close the tab.

Frequently Asked Questions

What discharge coefficient should I use?

About 0.61 for a sharp-edged plate; check ISO 5167 for precision work.

Does it include permanent pressure loss?

No, it uses the measured differential pressure.

Is data uploaded?

No.

Explore Related Micro-Tools