仕組みと内部処理
Run the pump into a measuring cylinder for a known time and enter the volume. The tool gives the real flow in mL/min, L/h and L/day and the correction against the label. Switch to dose mode to calculate how many millilitres of product reach a target ppm in a given volume and how long the pump must run.
使い方ステップ
Collect the pump output for a timed run at the working back-pressure.
Enter the volume and the time.
Compare the flow with the rated value.
Use dose mode to plan product volume and run time.
主な機能と特長
- Real flow in several units
- Deviation from rated flow with warning
- ppm dose to product volume
- Pump run time
計算ロジック・仕様・技術基準
Flow = volume ÷ time × 60. Product (mL) = system litres × ppm ÷ strength (g/L). Run time = product ÷ flow.
入出力の例・エッジケース
48 mL in 60 s
Calibration
48 mL/min, 2.88 L/h
仕様上の制限・精度に関するご注意
- • Flow changes with pressure, viscosity and tubing wear.
- • Check chemical compatibility and safety data before dosing.
ブラウザ内ローカル処理とプライバシー保護
一般的なWebツールは文書やメディアを外部サーバーへ送信します。定量ポンプ・チューブポンプ校正計算機 はお使いのブラウザタブ内のみで完結します:
入力テキストやファイルは端末内で処理され、外部の処理サーバーへアップロードされません。
作業内容や貼り付けたデータを保存・記録しません(通常の静的配信CDNリクエストのみ発生します)。
作業データはタブ内のメモリ上のみに保持され、リセットまたはタブを閉じると破棄されます。
よくある質問 (FAQ)
How often should I recalibrate?
Whenever you change tubing, product or pressure, and regularly for critical dosing.
What is 1 ppm?
One milligram per litre in water.
Is my data sent anywhere?
No.