How It Works Under the Hood
The short-form torque equation is T = K × F × d, where K is the nut factor that depends on lubrication. Choose the bolt size, property class and thread condition and either enter a torque to see the clamp force and percent of proof load, or enter a preload percentage to get the torque.
Step-by-Step Instructions
Choose the bolt size and property class.
Choose the thread condition.
Pick the direction and enter torque or preload percent.
Read clamp force, proof load and torque.
Key Features & Performance
- M3–M30 coarse thread
- Classes 4.8 to 12.9 and A2-70
- Lubrication presets
- Warnings near proof load
Methodology, Formulas & Technical Standards
T = K·F·d; proof load = proof strength × tensile stress area.
Worked Examples & Edge Cases
M10 8.8 at 40 N·m
Dry
About 20 kN, 57% of proof
Limitations, Scope & Accuracy Notes
- • Torque-based preload scatters by ±25–35%; critical joints need specified methods.
Local Browser Processing & Privacy
Traditional web converters upload your documents, snippets, or media files to remote servers. Bolt Torque to Preload (Clamp Force) Calculator runs inside your browser tab:
Your input text and files are processed locally without uploading payloads to a processing server.
Microdeck does not log or store the files or inputs you paste into tool workspaces (normal static hosting/CDN requests still load page assets).
Working outputs stay in your browser tab and are released when you reset the tool or close the tab.
Frequently Asked Questions
What is K?
About 0.2 for dry steel and lower when oiled.
Should I lubricate?
Only if the torque value you follow assumes it.
Is data uploaded?
No.