Microdeck.tools 100% In-Browser

Bolt Torque to Preload (Clamp Force) Calculator

New

Estimate bolt preload from tightening torque with the nut factor method, or the torque to reach a percent of proof load, for metric bolts M3 to M30.

100% In-Browser No Server Storage Instant Results

Did this tool save you time? Help keep Microdeck free and maintained. Completely optional · From $3.

How It Works Under the Hood

The short-form torque equation is T = K × F × d, where K is the nut factor that depends on lubrication. Choose the bolt size, property class and thread condition and either enter a torque to see the clamp force and percent of proof load, or enter a preload percentage to get the torque.

Step-by-Step Instructions

1

Choose the bolt size and property class.

2

Choose the thread condition.

3

Pick the direction and enter torque or preload percent.

4

Read clamp force, proof load and torque.

Key Features & Performance

  • M3–M30 coarse thread
  • Classes 4.8 to 12.9 and A2-70
  • Lubrication presets
  • Warnings near proof load

Methodology, Formulas & Technical Standards

T = K·F·d; proof load = proof strength × tensile stress area.

Worked Examples & Edge Cases

M10 8.8 at 40 N·m

Input
Dry
Output
About 20 kN, 57% of proof

Limitations, Scope & Accuracy Notes

  • • Torque-based preload scatters by ±25–35%; critical joints need specified methods.

Local Browser Processing & Privacy

Traditional web converters upload your documents, snippets, or media files to remote servers. Bolt Torque to Preload (Clamp Force) Calculator runs inside your browser tab:

Processed in This Tab

Your input text and files are processed locally without uploading payloads to a processing server.

No Tool Payload Logging

Microdeck does not log or store the files or inputs you paste into tool workspaces (normal static hosting/CDN requests still load page assets).

Tab Memory Lifecycle

Working outputs stay in your browser tab and are released when you reset the tool or close the tab.

Frequently Asked Questions

What is K?

About 0.2 for dry steel and lower when oiled.

Should I lubricate?

Only if the torque value you follow assumes it.

Is data uploaded?

No.

Explore Related Micro-Tools

Support Microdeck

Completely optional · From $3 · No account required

Choose an amount (USD):Selected:$5

Minimum support amount is $3 USD.

Completely optional · From $3 · Checkout opens on Gumroad.