仕組みと内部処理
Small ceramic and film capacitors print a code instead of a value. The first two digits are the number and the third digit is the power of ten, giving picofarads. An optional letter gives the tolerance, and a prefix such as 2A gives the rated voltage. The tool reads that code, also accepts notation like 4n7, and shows the value in pF, nF and µF.
使い方ステップ
Type the code exactly as printed, for example 104 or 473K.
Read the capacitance in the unit you need.
Check the tolerance and voltage lines when the code includes them.
主な機能と特長
- 3-digit EIA codes, 1–2 digit pF codes and 4n7-style notation
- Tolerance letters B to Z
- Common voltage codes such as 1H = 50 V and 2A = 100 V
- pF, nF and µF side by side
計算ロジック・仕様・技術基準
Value in pF = first two digits × 10^(third digit). Digit 8 multiplies by 0.01 and 9 by 0.1; digit 7 is not used.
入出力の例・エッジケース
104
Code 104
100,000 pF = 100 nF = 0.1 µF
473K
Code 473K
47 nF, ±10%
仕様上の制限・精度に関するご注意
- • Voltage codes vary slightly between makers; check the datasheet.
- • Electrolytic and tantalum capacitors usually print the value directly.
ブラウザ内ローカル処理とプライバシー保護
一般的なWebツールは文書やメディアを外部サーバーへ送信します。コンデンサ容量コード計算機 はお使いのブラウザタブ内のみで完結します:
入力テキストやファイルは端末内で処理され、外部の処理サーバーへアップロードされません。
作業内容や貼り付けたデータを保存・記録しません(通常の静的配信CDNリクエストのみ発生します)。
作業データはタブ内のメモリ上のみに保持され、リセットまたはタブを閉じると破棄されます。
よくある質問 (FAQ)
What does 104 mean on a capacitor?
10 followed by four zeros in picofarads: 100,000 pF, which is 100 nF or 0.1 µF.
What does the letter K mean?
It is the tolerance, ±10%. J is ±5% and M is ±20%.
Is the code sent anywhere?
No. Decoding happens in your browser.