仕組みと内部処理
Runtime = usable capacity ÷ average load. Usable capacity is the rated capacity times the percentage you can actually draw. For a duty cycle the average current is the active current times the active fraction plus the sleep current times the rest. For watt loads the capacity is converted to watt-hours with the battery voltage.
使い方ステップ
Enter battery capacity in mAh and its voltage, and the usable percentage.
Choose a constant current or power load, or an active/sleep cycle.
Enter the load values.
Read the runtime in hours and days.
主な機能と特長
- Current (mA) or power (W) loads
- Duty cycle with separate active and sleep currents
- Usable capacity setting for aging, cutoff voltage and temperature
- Readable duration such as 2 d 2 h
入出力の例・エッジケース
Constant load
2000 mAh, 80% usable, 120 mA
13 h 20 min
Power bank
10,000 mAh at 3.7 V, 70% usable, 5 W
5 h 11 min
25.9 Wh ÷ 5 W.
仕様上の制限・精度に関するご注意
- • Real capacity falls with high discharge rates, cold temperatures and age; use a lower usable percentage to be safe.
- • Self-discharge matters for multi-year projects and is not modelled.
ブラウザ内ローカル処理とプライバシー保護
一般的なWebツールは文書やメディアを外部サーバーへ送信します。バッテリー駆動時間計算機 はお使いのブラウザタブ内のみで完結します:
入力テキストやファイルは端末内で処理され、外部の処理サーバーへアップロードされません。
作業内容や貼り付けたデータを保存・記録しません(通常の静的配信CDNリクエストのみ発生します)。
作業データはタブ内のメモリ上のみに保持され、リセットまたはタブを閉じると破棄されます。
よくある質問 (FAQ)
What usable percentage should I use?
About 80% is a reasonable default for lithium cells, less for old cells, cold weather or high current.
How do I convert a power-bank rating?
Power banks quote cell capacity at 3.7 V. Enter that voltage and a usable value near 65 to 75% to allow for conversion losses.
Does the tool store anything?
No.